Hotline:

00 0000 0000

Email

info@truck-carepc.com

Bobcat Service Analyzer V87.07 Diagnostic Software 2019

  • $180.00
  • Brands BOBCAT
  • Product Code: Bobcat Service Analyzer V87.07 Diagnostic Software 2019
  • Availability: In Stock

Tags: Bobcat Service Analyzer V87.07 Diagnostic Software 2019

Bobcat Service Analyzer V87.07 Diagnostic Software 2019
[05/2019]
Diagnostic Software Bobcat Service Analyzer V87.07 Diagnostic Software 2019 
Type of catalogue: Diagnostic Software
Make: Bobcat
Region: WorldWide
Inclusive
 languages: Multilanguage

Availibility Instant Download , or dvd
OS:  Windows 7 32 bit, Windows 7 64 bit, Windows 8/8.1 32 bit, Windows 8/8.1 64 bit,

IS INCLUSE KG  FOR CHANGE LEVEL !!!!!


   
 


 


Bobcat Service Analyzer contains a tool for programming and diagnosing the Bobcat technique. Software version 87.07 contains a list of fixes and updates that you can read for a better understanding of the program.

Diagnostic tools Bobcat help you find out whether there is a problem with our equipment and solve in time with the diagnostic tool to avoid potential danger. This software will allow you to familiarize yourself with the various technical information and functions of this program, with which you can correctly diagnose your equipment and prevent premature breakdowns.

Diagnostic tools Bobcat is intended for programming, diagnostic, service log, and calibration:
 -  Software updates
 - Change SN/Options
 - Clear Controller Data.
 - Drive pump calibration status
 - Panel
 - Remote Control
 - System
 - Vitals,
 - Edit diagnostic screens
 - Interactive tests and etc.
 With help step by step instructions, you can do diagnostic your equipment.
 Service Analyzer Bobcat a very simple interface, support multilanguage includes  English and recorded on 1 DVD-DL, which consists of basic standard tools. Below you can see release notes.

Service Analyzer V87.07 - 22 May 2019

1. New TLS Gateway Software (V6.40), TLS Drive
    Software (V6.40) and TLS Workgroup Software
    (V6.40) to support new controllers with part
    numbers 7273600, 7273601, and 7273602.

2. New Manbasket Software (V1.40) and GACD2
    Software (V1.20) to support new controller
    with part number 7273603.

3. Support added for the following machines:
    - D35*J**R: B4WV11001+
    - D35ZK*ER: B4CS11001+
    - D42*J**M: B4WW11001+
    - D42*J**R: B4YF11001+
    - D50*J**M: B4WY11001+
    - D50*J**R: B4YG11001+

4. Support added for 7" Display on the
    following machines:
    - E85*J**R: B48413701+

***********************************************
 Service Analyzer V87.06 - 14 May 2019

1. New GACD Software (V8.9)
    a. Support added for the Box Blade HD
       - B4T900101+

2. New Loader Deluxe Software (V7.5)
    a. Support added for the Box Blade HD

3. New MX Primary (V4.5) and Secondary (V2.3) software
    a. Initial support for 7" display

   b. Support for the following machines:
       - D17ZKA*M: B3Y911001+
       - D27ZK*ER: B4BB11001+
       - D35ZK*ER: B4CS11001+  
   
 ***************************************
 Service Analyzer V87.05 - 30 April 2019

1. Support for Bob-Dock added on the
    following machines:
    - S740H***A: B3BT11805
    - T740H***A: B3CA11805
    - S770H***B: AT5A11720
    - T770H***B: AT6312720
    - A770H***B: AT5J11380
    - T750H***B: AT5T11743
    - T630H***B: AJDT13778
    - T650H***B: ALJG19317
    - S630H***B: AHGL12984
    - S650H***B: ALJ818497

2. Support added for the following
    machines:
    - E26*K**R: B4S911001

3. New Loader M4 Drive Software
    (V14.11)
    a. Decrease hydrostatic pump gain
       for the following models:
       - T630****A - A7PU16275+
       - T630H***B - AJDT16750+
       - T650****A - A3P021700+
       - T650***EA - A3P115475+
       - T650H***B - ALJG29650+
       - T650H**EB - B2KZ13900+

***************************************
 Service Analyzer V87.04 - 5 April 2019

1. Support for Bob-Dock added on the
    following machine:
    - T650H***B: ALJG28632

2. Boom down movement control ramps
    improved on following Telehandler
    machines:
    - TL35.70: ANL714000+, ANMG14000+,
               AVM114000+, AVM614000+,
               B3ZS11001+, B3ZT11001+
    - TH.7035: AR3914000+, AR3D14000+,
               B3C414000+, B3C514000+,
               B3ZZ11001+, B41111001+
    - V723:    B4C311001+

3. Corrected boom movement limitations
    in case of some LLM faults on following
    Telehandler models:
    TL30.60, TL26.60, TH.6030, TL30.70, TH.7030,
    T35.105, T35.105L, T36.120SL, T35.130S,
    T35.130SLP, T35.140S, T41.140SLP, T40.180SLP

***************************************
 Service Analyzer V87.03 - 27 March 2019

1. Support added for the following
    machines:
    - S70*K***B: B4TY11001+
    - S70*K**EB: B4UC11001+
    - S590H*D*A: B4TP11001+
    - E26*K**R:  B4S911001+

2. New Loader Gateway Software
    (V15.01)
    - Fixes issue with switched power
      sometimes remaining off on key on.

***************************************
 Service Software V87.02 - 4 Mar 2019

1. New Loader Auxiliary Software
    (V5.1)
    - Fixes issue with Remote ACD
      attachments (Chipper, Concrete
      Pump, etc.) when activating
      auxiliaries from the attachment.
   
 2. Support for Bob-Dock added on the
    following machines
    - S740H***A: B3BT14668+
    - T740H***A: B3CA15491+
    - S770H***B: AT5A13544+
    - T770H***B: AT6319318+
    - S770H**EB: B3BV11888+
    - T770H**EB: B3BW13133+
    - A770H***B: AT5J12503+
    - A770H**EB: B3BU11707+
    - T630H***B: AJDT16592+
    - S630H***B: AHGL14606+
    - S650H***B: ALJ825891+

3. Include boom float option on
    following TLS machines:
    - TL26.60   B3G615001+, B3G815001+,
                B3GA15001+, B3GC15001+,
                B3YF15001+, B3ZH15001+
    - TL30.60   B3G415001+, B3G715001+,
                B3G915001+, B3GB15001+,
                B3YD15001+, B3Z815001+
    - TL30.70   B4AY15001+, B4AZ15001+,
                B4B215001+, B4B315001+
    - TH.6030   B3GD15001+, B3GE15001+,
                B3GF15001+, B3GG15001+,
                B3ZL15001+, B3ZM15001+
    - TH.7030   B4DW15001+, B4DZ15001+
    - TL34.65HF B41N17001+, B41P17001+
    - TL35.70   ANL716001+, ANMG16001+,
                AVM116001+, AVM616001+,
                B3ZS17001+, B3ZT17001+
    - TL38.70HF AHT416001+, AVDV16001+,
                AVKJ16001+, AVKM16001+,
                B3ZU17001+, B3ZV17001+
    - TL43.80HF B4BT11001+, B4BU11001+,
                B4BY11001+, B4BZ11001+,
                B4P711001+
    - TH.6534   B41S17001+, B41R17001+
    - TH.7035   AR3916001+, AR3D16001+,
                B3C416001+, B3C516001+,
                B3ZZ17001+, B41117001+
    - TH.7038   AT7A16001+, AVDZ16001+,
                B3C616001+, B3C716001+,
                B41217001+, B41317001+
    - TH.8043   B4BV11001+, B4BW11001+,
                B4C111001+, B4C211001+,
                B4P811001+

4. Update TLS Bobcat engine ECU
    software to include 300 sec torque
    derate before engine shutdown in
    case of critical failure on
    following machines:
    - TL26.60   B3YG11001+, B3ZJ11001+,
                B3ZH11001+, B3YF11001+,
    - TL30.60   B3YE11001+, B3Z911001+,
                B3Z811001+, B3YD11001+,
    - TL30.70   B4B111001+, B4B211001+,
                B3ZK11001+, B4B311001+
    - TH.6030   B3ZL11001+, B3ZM11001+,
    - TH.7030   B4DW11001+, B4DZ11001+
    - V519      B3YH11001+,
    - TL35.70   B3ZS11001+, B3ZT11001+
    - TL34.65HF B41N11001+, B41P11001+
    - TL38.70HF B3ZU11001+, B3ZV11001+,
                AVDV14000+, AVKJ14000+,
                AHT414000+, AVKM14000+
    - TL43.80HF B4BY11001+, B4BZ11001+,
                B4P711001+, B4BT11001+,
                B4BU11001+
    - TH.7035   B3ZZ11001+, B41111001+
    - TH.6534   B41R11001+, B41S11001+
    - TH.7038   B41211001+, B41311001+,
                AVDZ14000+, AT7A14000+,
                B3C614000+, B3C714000+
    - TH.8043   B4C111001+, B4C211001+,
                B4P811001+, B4BV11001+,
                B4BW11001+
    - V723      B4C311001+
    - T35.105   B41511001+, B41411001+
    - T35.105L  B41711001+, B41611001+
    - T36.120SL B41911001+, B41811001+
    - T35.130S  B41B11001+, B41A11001+
    - T35.130SLP B41D11001+, B41C11001+
    - T35.140S  B41G11001+, B41F11001+
    - T41.140SLP B41K11001+, B41H11001+
    - T40.180SLP B41M11001+, B41L11001+

5. Service Analyzer V5.17 Release
    - Added warning when TLS engine
      updates require main
      controller updates.

   - New engine software included:
      300 sec torque derate in case of
      critical error code then engine
      shutdown instead of immediate
      engine shutdown.
   
    - Fixed bug that caused portions of
      the English postscript of
      translated logs to not be in
      English.

   - Fixed data from diagnostic
      screens being captured when
      closing the file dialog, instead
      of when the “Save Data” button in
      the gear menu was pressed.
   
    - Improved handling of invalid
      default service log directory
      settings.

***************************************
 Service Software V87.01 - 19 Feb 2019

1. Reverting Loader Auxiliary Software
    from V5.0 to V4.03.  Issue found
    that prevents Remote ACD attachments
    (Chipper, Concrete Pump, etc.) from
    activating auxiliaries from the
    attachment.

***************************************
 Service Software V87.00 - 11 Feb 2019

1. New Toolcat Drive Software (V4.10)
    a. Improved auxiliary control when
       braking.

   b. Improved throttle fault
       detection.

   c. Improved swash plate fault
       detection.

2. New Loader M4 Drive Software
    (V14.10)
    a. Decrease hydrostatic pump gain
       for the following models:
       - T740H***A - B3CA16100+
       - T770****A - A3P816575+
       - T770***EA - A3P913375+
       - T770H***B - AT6321000+
       - T770H**EB - B3BW13300+
       - T870E***B - B47H11300+
       - T870H***C - B47C13700+
       - T870H**EC - B47L11500+

1. Telehandler Software Update (Workgroup
    V5.6; Drive V6.1; and Gateway V5.2)
    a. Creation of following serial numbers
       for 4.3 T machines:
      - B4BT11001+
      - B4BU11001+
      - B4BV11001+
      - B4BW11001+
      - B4BY11001+
      - B4BZ11001+
      - B4P711001+
      - B4C111001+
      - B4C211001+
      - B4P811001+
     
    b. Activated automatic suspension
       function on following serial numbers:
      
       PF1:
       B3G415001+, B3G615001+, B3G715001+
       B3G815001+, B3G915001+, B3GA15001+
       B3GB15001+, B3GC15001+, B3GD15001+
       B3GE15001+, B3GF15001+, B3GG15001+
       B3Z815001+, B3ZH15001+, B3YD15001+
       B3YF15001+, B3ZL15001+, B3ZM15001+
       B4AY15001+, B4AZ15001+, B4B215001+,
       B4B315001+, B4DW15001+, B4DZ15001+


       PF2:
       B41N17001+, B41P17001+, B41R17001+,
       B41S17001+, ANL716001+, ANMG16001+,
       AVM116001+, AVM616001+, AR3916001+,
       AR3D16001+, B3C416001+, B3C516001+,
       B3ZS17001+, B3ZT17001+, B3ZZ17001+,
       B41117001+, B4C317001+, AVDV16001+, 
       AHT416001+, AVKJ16001+, AVKM16001+,
       AVDZ16001+, AT7A16001+, B3C616001+,
       B3C716001+, B3ZU17001+, B3ZV17001+,   
       B41217001+, B41317001+, B4BT11001+,
       B4BU11001+, B4BV11001+, B4BW11001+,
       B4BY11001+, B4BZ11001+, B4P711001+,
       B4C111001+, B4C211001+, B4P811001+


    c. Improved interrupt power monitoring on
       Workgroup and Auxiliary controllers.

Service Software V86.02 - 21 Feb 2018:
 1. Removed Auto-Idle as an option for SJC loaders with Bobcat Engines. Before this was a selectable option. The feature is defaulted to on for these machines.
 2. Loader software update for Bobcat Engine machines.
 Adds two new codes (M0144 and M0145). Related to air filter plugging for loaders with M4 Gateway Controller and Bobcat Engines. Codes are set and engine power is de-rated after operating 8 hours with a plugged air filter code (M0117).
 3. New telehandler Drive software (V5.9):
    - Transmission softening for following machines (all platforms):
 TL30.60, TL26.60, V519, TH.6030, TL30.70, TH.7030, TL38.70HF, TH.7038, TL34.65HF, TH.6534, TL35.70, TH.7035, T35.105, T35.105L, T36.120SL, T35.130S, T35.130SLP, T35.140S, T41.140SLP, T40.180SLP.
    - Reduction of engine speed to apply park brake later when the engine shut down occurs on following machines (all platforms Stage 4):
 TL30.60, TL26.60, TH.6030, TL30.70,TH.7030, TL34.65HF, TH.6534, TL35.70, TH.7035, TL38.70HF, TH.7038, T35.105, T35.105L, T36.120SL, T35.130S, T35.130SLP, T35.140S, T41.140SLP, T40.180SLP
 4. New telehandler Gateway software (V5.9):
    - Current ECU and DCU software version displayed on Service Analyzer for Stage 4 machines.





Write a review